MicroController Pros Home Page My Account  Cart Contents  Checkout  

****Note: We no longer process and ship international orders. Only orders from USA and Canada are now accepted.****
You can place international orders for our products on E-Bay. Just copy the item's title description from our website and paste it into the search box on E-Bay and place your order there.

  Store » Test & Measurement » Logic Analyzers » LA-ProtocolTrigger My Account  |  Cart Contents  |  Checkout   
Quick Find
 
Enter keywords to find the product you are looking for in the Quick Find field above

or use
Advanced Search
Categories
Accessory Boards->
8051->
ADI Blackfin
Arduino->
ARM->
Atmel AVR->
Cypress PSoC
Freescale->
FTDI->
Locktronics
Microchip PIC->
MIPS
Parallax->
Renesas
Silicon Labs
ST Microelectronics->
Texas Instruments->
Tibbo->
Books->
Displays->
E-Blocks->
EEPROM/EPROM/FLASH
Embedded Ethernet->
Embedded Software->
I/O Modules->
Parts & Components->
Pick & Place Tools
Programmable Logic (PLD)
Prototype PCBs->
Robotics
ROM/Flash Emulators
Test & Measurement->
  Data Loggers
  Function Generators
  Hand Tools
  IC Testers
  Lab Power Supplies
  Logic Analyzers->
    Accessories
  Oscilloscopes
  Protocol Analyzers
  GPIB Converters
Tutorial Software
Universal Programmers->
Wireless->
Information
Intro to Embedded Tools
Embedded News Digest
Useful Resources
Shipping & Returns
Warranty & Liability
Privacy Notice
Conditions of Use
Contact Us
Protocol Analyzer Trigger plugin for ZeroPlus logic analyzers US$52.00

LA-ProtocolTrigger
Protocol Analyzer Trigger plugin for ZeroPlus logic analyzers

This software add-on is used to activate Protocol Analyzer Packet Trigger capability for ZeroPlus logic analyzer models LAP-C-16032, LAP-C-16064, LAP-C-16128, LAP-C-162000, LAP-C-32128, and LAP-C-321000.

The Packet Trigger function of the Protocol Analyzer can be used to help you find the correct position in complex packets. In the case of this function, the options of the Protocol Packet are determined by the different Protocol Analyzers. Take the I2C for an example. When we do the Packet Trigger function for the packets of the I2C Protocol Analyzer, the protocol packets can be selected from the options, such as START, ADDRESS, READ, WRITE, A-ACK, D-ACK, D-NACK, A-NACK, ERROR and STOP. The Value of the Protocol Packet can be entered according to the requirements of the I2C Protocol Analyzer.

Protocol Analyzer Trigger Plugin Operation

Step 1


When the Protocol Analyzer Module is activated, choose the Bus Trigger Setup item from the pull-down menu of the Trigger or Bus Trigger Setup icon on the toolbars, or single-click the Trigger column to open the Bus Trigger dialog box, then select the Protocol Analyzer Trigger tab to open the Protocol Analyzer Trigger dialog box.


Step 2


If you have not registered this function, the Protocol Analyzer Trigger dialog box will be grayed-out. At this time, you can press the Register button to open the Register dialog box and enter your serial key to finish the registration.


Step 3


After the Protocol Analyzer Trigger function is registered, you can return the Protocol Analyzer Trigger dialog box to set the relative parameters.


Step 4


Take the I2C Protocol Analyzer for an example. Set the Value of the DATA to 0X4A and click the Single Run icon on the logic analyzer software. After the trigger is finished, the position of the T Bar will be seen at position 0X4A in the Waveform Display Area.

Ordering for Existing Users

If you are purchasing this add-on for a ZeroPlus logic analyzer that you already own, please use the Comments field after checkout to provide the model and serial number of the unit for which this should be registered. We need that in order to create a license key for you.


This product was added to our catalog on Friday 27 April, 2012.

Reviews

Customers who bought this product also purchased
Protocol Simulator Board 1, Generator of 46 Signals for TestingProtocol Simulator Board 1, Generator of 46 Signals for TestingUS$85.00

Logic & Protocol Analyzer, 16 ch.@128kb, 100Hz-200MHz, USB PowerLogic & Protocol Analyzer, 16 ch.@128kb, 100Hz-200MHz, USB PowerUS$439.00

16-channel signal connector cable set, 40cm16-channel signal connector cable set, 40cmUS$15.00

Logic & Protocol Analyzer, 16 ch.@64kb, 100Hz-75MHz, USB PowerLogic & Protocol Analyzer, 16 ch.@64kb, 100Hz-75MHz, USB PowerUS$230.00

Logic & Protocol Analyzer, 16 ch.@32kb, 100Hz-75MHz, USB PowerLogic & Protocol Analyzer, 16 ch.@32kb, 100Hz-75MHz, USB PowerUS$209.00

Shopping Cart more
0 items
What's New? more
Solar Panel, 2W, 6V/378mA, 3.5x1.1mm Barrel, 5.5x2.1mm Adapter
Solar Panel, 2W, 6V/378mA, 3.5x1.1mm Barrel, 5.5x2.1mm Adapter
US$19.00
Tell A Friend
 

Tell someone you know about this product.
Notifications more
NotificationsNotify me of updates to Protocol Analyzer Trigger plugin for ZeroPlus logic analyzers
Reviews more
Write ReviewWrite a review on this product!
  Monday 14 October, 2024   List of all our Products

Copyright © 2003-2017 MicroController Pros LLC
Powered by osCommerce