The MSM-4S is a high performance 4-port industrial serial communication Mini-PCI module. Port P1 and P2 can be independently configured as RS-232, RS-422 or RS-485 serial Interface by adjusting the on-board DIP switch. Port P3 and P4 are dedicated RS-232 serial interface. Four D-Sub 9-pin to 2x5 IDC ribbon cables are included for connecting to the board's serial port headers. - Mini-PCI interface, 50 mm height only
- 2x RS-232/422/485 ports, select by DIP switch
- 2x dedicated RS-232 ports
- Baud rate from 50bps to 921.6Kbps
- 16C950 compatible UART with 128-byte FIFO
- Over 700Kbps data throughput for each port running concurrently
- Hardware auto-direction control for RS-485
- Software drivers included for Windows 2003/XP/2000/NT/98/95/ME and Linux
16C950 Compatible High Speed UART A high-performance 16C950 compatible UART chip with 128-byte FIFO is used for MSM-4S to improve the transmission throughput and reduce the host computer's CPU loading. Over 700Kbps data throughput for each port is guaranteed when all ports run concurrently. 4-port RS-232/422/485 Module Specifications Hardware - Bus: Mini-PCI
- IRQ: one IRQ for all serial ports
- No. of Boards: 4 max. (share the same IRQ)
- UART: Oxford 16mPCI954 or compatible
- Connector: 10-pin header for each serial port
- Protection: 15KV ESD for all signals
Serial Port Setting - P1: RS-232/422/485, select by DIP SW S1,S2
- P2: RS-232/422/485, select by DIP SW S3,S4
- P3,P4: RS-232 only
Serial Port Parameters - Baud Rate: 50bps to 921.6 Kbps
- Parity: None, Even, Odd, Mark, Space
- Data Bits: 5,6,7,8 bits
- Stop Bit: 1, 1.5, 2 bits
- Flow Control: RTS/CTS, XON/XOFF, None
- Hardware auto-direction control for RS-485
Drivers - Windows 2003/XP/2000/NT/98/95/ME
- Linux 2.4.12 and above
General - Power consumption: 200mA@3.3VDC
- Dimension: 59 x 50 mm
- Operation Temperature: 0~55C(32~131F),5~95% RH
- Storage Temperature: -20~85C,5~95% RH
- Regulation: CE/FCC Class A compliant
- Warranty: 2 years
Pin Assignment PIN | RS-232 | RS-422 | RS-485 | 1 | DCD | Tx- | --- | 2 | DSR | --- | --- | 3 | Rx | Tx+ | --- | 4 | RTS | --- | --- | 5 | Tx | Rx+ | Data+ | 6 | CTS | --- | --- | 7 | DTR | Rx- | Data- | 8 | RI | --- | --- | 9 | GND | GND | GND | 10 | --- | --- | --- | Software Utility Switch Setting The MSM-4S's port P1 and P2 can operate as either RS-232, RS-422 or RS-485. The DIP switch S1 and S2 are used together to adjust the port P1; the S3 and S4 are used for the port P2. DIP Switch S1 and S3 Type | 1 | 2 | 3 | 4 | 5 | 6 | RS-232 | ON | OFF | OFF | ON | OFF | ON | RS-422 | OFF | ON | OFF | OFF | ON | OFF | RS-485 | OFF | ON | ON | OFF | ON | OFF | DIP Switch S2 and S4 Type | 1 | 2 | 3 | 4 | 5 | 6 | RS-232 | OFF | ON | OFF | ON | OFF | ON | RS-422 | ON | OFF | ON | OFF | ON | OFF | RS-485 | ON | OFF | ON | OFF | ON | OFF |
|